عطل كودي
رقم: Code: 0030
Description:FAX
control PWB system error Processing with the fax software was disabled due to a
software problem.
Causes:FAX
control PWB
Remedy:1. Turn
the main power swtch off and after 5 seconds, re-mount the FAX controller PWB,
then turn power on. 2. Reinstall the fax software. 3. Replace the FAX control
PWB.
عطل كودي
رقم: Code: 0060
Description:Mainboad
type mismatch
Causes:Engine
PWB
Remedy:Replace
the engine PWB
عطل كودي
رقم: Code: 0070
Description:FAX
control PWB incompatible detection error Abnormal detection of FAX control PWB
incompatibility In the initial communication with the FAX control PWB, any
normal communication command is not transmitted.
Causes:FAX
control PWB (The FAX PWB installed will not be the one designed for the
machine.)
Remedy:1.
Install the FAX system designed for the model. 2. Reinstall the fax software.
عطل كودي
رقم: Code: 0100
Description:Backup
memory device error
Causes:Flash
memory (Main PWB)
Remedy:1. Turn
the main power swtch off and after 5 seconds, then turn power on. 2. Replace
the main PWB
عطل كودي
رقم: Code: 0120
Description:MAC
address data error For data in which the MAC address is invalid.
Causes:Flash
memory (Main PWB)
Remedy:1. Turn
the main power swtch off and after 5 seconds, then turn power on. 2. Check the
MAC address on the network status page. 3. If it is blank, obtain the data with
its MAC address written from the service support and install. 4. Replace the
main PWB
عطل كودي
رقم: Code: 0130
Description:Backup
memory read/write error (main PWB) Mismatch between writing data and reading
data successively.
Causes:Main PWB
Remedy:Replace
the main PWB and check for correct operation
عطل كودي
رقم: Code: 0140
Description:Backup
memory data error (main PWB) When the data read from NAND is abnormalities
Causes:Main PWB
Remedy:Replace
the main PWB and check for correct operation
عطل كودي
رقم: Code: 0150
Description:Backup
memory read/write error (engine PWB) No response is issued from the device in
reading/writing for 5 ms or more and this problem is repeated 5 times
successively. Mismatch of reading data from 2 locations occurs 8 times
successively. Mismatch between writing data and reading data occurs 8 times
successively.
Causes:EEPROM
(Engine PWB)
Remedy:1. Turn
the main power swtch off and after 5 seconds, then turn power on. 2. Check that
the EEPROM is peroperly installed on the engine PWB and reinstall it. 3.
Replace the engine PWB . 4. Check the EEPROM and if the data are currupted,
contact the service support.
عطل كودي
رقم: Code: 0160
Description:Backup
memory data error (engine PWB) Reading data from EEPROM is abnormal.
Causes:EEPROM
Remedy:1. Turn
the main power swtch off and after 5 seconds, then turn power on. 2. Execute
U021 – memory initializing. 3. If the EEPROM data are currupted, contact the
service support.
عطل كودي
رقم: Code: 0170
Description:Billing
counting error The values on the main circuit PWB and on the engine do not
match for any of charging counter, life counter, and scanner counter.
Causes:EEPROM,
Main PWB, Engine PWB
Remedy:EEPROM
1. Check that the EEPROMs installed in the main PWB and the engine PWB are
correct and, if not, use the correct EEPROM for the model. 2. If the EEPROM
data are currupted, contact the service support.
Main PWB Replace the main PWB.
Engine PWB Replace the engine PWB.
عطل كودي
رقم: Code: 0180
Description:Machine
number mismatch Machine number of main and engine does not match.
Causes:Data
damage of EEPROM.
Remedy:1.
Confirm the machine data for the main and engine units by using U004. 2. If the
serial number data of different models is alternately displayed, install the
correct EEPROM in the PWB of the wrong serial number data. 3. Contact the
Service Support.
عطل كودي
رقم: Code: 0350
Description:Panel
PWB communication error (electronic volume I2C communication error) NACK is
received during I2C communication -> retried 5 times -> rebooting command
sent -> retried 5 times If NACK is still received.
Causes:Operation
PWB Main PWB
Remedy:Operation
PWB 1. Turn the main power swtch off and after 5 seconds, then turn power on.
2. Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. Operation panel PWB 1 (YC10) and Main PWB
(YC12) 3. If the wiring is disconnected, shorted or grounded, replace the wiring.
4. Replace the operation panel PWB 1.
Main PWB Replace the main PWB.
عطل كودي
رقم: Code: 0640
Description:Hard
disk error The hard disk cannot be accessed.
Causes:HDD,
Main PWB
Remedy:HDD 1.
If an abnormal noise is heard from the HDD, replace the HDD. 2. Check the SATA
wiring between the HDD and the main circuit PWB for loose connection,
disconnection and damages, and that it is connected into the correct terminal.
Main PWB: YC2,YC32 3. Replace the SATA cable. 4. Execute U024 to initialize
(FULL) the HDD. 5. If an error is detected after executing U024, replace the
HDD.
Main PWB Replace the main PWB.
عطل كودي
رقم: Code: 0650
Description:FAX
image storage paircheck error The SSD used in the other main unit was
installed.
Causes:SSD,
Main PWB
Remedy:SSD 1. When
installing the SSD used once, replace with the correct SSD. 2. When installing
the SSD used once, execute [FAX Data CLEAR] at U671. 3. Be sure to install the
SSD to the connector on the main PWB. 4. Replace with the new SSD.
Main PWB Replace the main PWB.
عطل كودي
رقم: Code: 0660
Description:Hard
disk encryption key error
Causes:EEPROM,
HDD, Main PWB
Remedy:EEPROM
1. Execute U004 if this occurs after the EEPROM has been changed.
HDD 1. If an abnormal noise is heard from the HDD, replace the HDD. 2. Check
the SATA wiring between the HDD and the main circuit PWB for loose connection,
disconnection and damages, and that it is connected into the correct terminal.
Main PWB: YC2,YC32 3. Replace the SATA cable. 4. Execute U024 to initialize
(FULL) the HDD. 5. If an error is detected after executing U024, replace the
HDD.
Main PWB Replace the main PWB.
عطل كودي
رقم: Code: 0670
Description:Hard
disk overwriting erasure error
Causes:HDD, Main
PWB
Remedy:HDD 1.
If an abnormal noise is heard from the HDD, replace the HDD. 2. Check the SATA
wiring between the HDD and the main circuit PWB for loose connection,
disconnection and damages, and that it is connected into the correct terminal.
Main PWB: YC2,YC65 3. Replace the SATA cable. 4. Execute U024 to initialize
(FULL) the HDD. 5. If an error is detected after executing U024, replace the
HDD.
Main PWB Replace the main PWB.
عطل كودي
رقم: Code: 0680
Description:SSD
error The SSD cannot be accessed, or the error occurs when accessing to the
SSD.
Causes:SSD,
Main PWB
Remedy:SSD 1.
Turn the power switch and the main power switch off. After 5s passes, turn the
main power switch and the power switch on. 2. Reinstall the SSD on the main
PWB. 3. Retrieve the SSD storage data at U026, and then initialize the SSD at
U024. 4. Replace the SSD.
Main PWB Replace the main PWB.
عطل كودي
رقم: Code: 0800
Description:Image
processing error JAM010X is detected twice.
Causes:Main PWB
Remedy:Replace
the main PWB.
عطل كودي
رقم: Code: 0830
Description:FAX
control PWB flash program area checksum error A checksum error occurred with
the program of the FAX control PWB.
Causes:FAX
software, FAX control PWB
Remedy:FAX
software 1. Reinstall the fax software.
FAX control PWB 1. Execute initializing by U600. 2. Replace the FAX control
PWB.
عطل كودي
رقم: Code: 0840
Description:Faults
of RTC (“Time for maintenance T” is displayed) [Check at power up] The RTC
setting has reverted to a previous state. The machine has not been powered for
5 years (compared to the settings stored periodically in the EEPROM). The RTC
setting is older than 00:01 on January 1, 2000. [Checked periodically (in 5-
minute interval) after powered up] The RTC setting has reverted to a state
older than the last time it was checked. 10 minutes have been passed since the
previous check. After C840 is detected, the machine enters in disconnection
mode after the main power switch has been switched on and off and indicates
‘Maintenance T.’
Causes:Battery
( main PWB), Main PWB
Remedy:Battery
( main PWB) 1. Make sure that the back-up batteries on the main PWB are not
short-circuited. 2. Reset Maintenance T by executing U906. 3. If the same C
call is displayed when power is switched on and off, replace the back up
battery. 4. If communication error (due to a noise, etc.) is present with the
RTC on the main circuit PWB, check the PWB is properly grounded.
Main PWB Replace the main PWB.
عطل كودي
رقم: Code: 0870
Description:PCFAX
control PWB to main PWB high capacity data transfer error High-capacity data
transfer between the FAX control PWB and the main PWB of the machine was not
normally performed even if the data transfer was retried the specified times.
Causes:FAX
control PWB, HDD, Main PWB
Remedy:FAX
control PWB 1. Turn the main power swtch off and after 5 seconds, re-mount the
FAX controller PWB, then turn power on. 2. Replace the FAX control PWB.
HDD Execute U024 to initialize the HDD.
Main PWB Replace the main PWB.
عطل كودي
رقم: Code: 0920
Description:Fax file
system error The backup data is not retained for file system abnormality of
flash memory of the FAX control PWB.
Causes:FAX
control PWB
Remedy:1.
Execute initializing by U600 (Refer to the FAX service manual). 2. Replace the
FAX control PWB.
عطل كودي
رقم: Code: 0980
Description:24 V
power down detect If a 24V power disconnection signal is observed and a 12V
power disconnection signal is observed simultaneously for one second.
Causes:Power
source PWB
Remedy:1. Check
the +24V output is given at YC5 of the power circuit PWB. 2. Replace the power
source PWB
عطل كودي
رقم: Code: 1010
Description:Lift
motor 1 error Lift error that occurs when the lock signal does turn off 510
msec in succession after turning on the cassette lift motor 1 has occurred five
times in succession.
Causes:Cassette
lift base elevating mechanism. Lift motor 1. Lift sensor 1. Engine PWB
Remedy:Cassette
lift base elevating mechanism Check that the cassette base can be manipulated
smoothly, if not, repair or replace.
Lift motor 1 1. Check that the cassette base has been ascended. 2. Check the
drive gear can rotate or they are not unusually loaded and, if necessary,
replace. 3. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Lift motor 1 and Engine PWB
(YC13) 4. If the wiring is disconnected, shorted or grounded, replace the
wiring. 5. Replace the lift motor 1.
Lift sensor 1 1. Check that the sensor is correctly positioned. 2. Confirm that
the wiring connector is firmly connected and, if necessary, connect the
connector all the way in. Lift sensor 1 and Engine PWB (YC17) 3. If the wiring
is disconnected, shorted or grounded, replace the wiring. 4. Replace the lift
sensor1.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 1020
Description:Lift
motor 2 error Lift error that occurs when the lock signal does turn off 510
msec in succession after turning on the cassette lift motor 2 has occurred five
times in succession.
Causes:Cassette
lift base elevating mechanism. Lift motor 2. Lift sensor 2. Engine PWB
Remedy:Cassette
lift base elevating mechanism Check that the cassette base can be manipulated
smoothly, if not, repair or replace.
Lift motor 2 1. Check that the cassette base has been ascended. 2. Check the
drive gear can rotate or they are not unusually loaded and, if necessary,
replace. 3. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Lift motor 2 and Engine PWB
(YC17) 4. If the wiring is disconnected, shorted or grounded, replace the
wiring. 5. Replace the lift motor 2.
Lift sensor 2 1. Check that the sensor is correctly positioned. 2. Confirm that
the wiring connector is firmly connected and, if necessary, connect the
connector all the way in. Lift sensor 2 and Engine PWB (YC17) 3. If the wiring is
disconnected, shorted or grounded, replace the wiring. 4. Replace the lift
sensor 2.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 1030
Description:PF lift
motor 1 error (paper feeder) After cassette 3 is inserted, PF lift sensor 1
does not turn on within 12 s. This error is detected 5 times successively.
During driving the motor, the lift overcurrent protective monitor signal is
detected for 1 s or more 5 times successively. However, the first 1 s after
motor is turned on is excluded from detection.
Causes:Cassette
lift base elevating mechanism. PF Lift motor 1. PF Lift sensor 1. PF main PWB
Remedy:Cassette
lift base elevating mechanism Check that the cassette base can be manipulated
smoothly, if not, repair or replace.
PF Lift motor 1 1. Check that the cassette base has been ascended. 2. Check the
drive gear can rotate or they are not unusually loaded and, if necessary,
replace. 3. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. PF Lift motor 1 and PF main
PWB 4. If the wiring is disconnected, shorted or grounded, replace the wiring.
5. Replace the PF lift motor 1.
PF Lift sensor 1 1. Check that the sensor is correctly positioned. 2. Confirm
that the wiring connector is firmly connected and, if necessary, connect the
connector all the way in. PF Lift sensor 1 and PF main PWB 3. If the wiring is
disconnected, shorted or grounded, replace the wiring. 4. Replace the PF lift
sensor 1.
PF main PWB Replace the PF main PWB.
عطل كودي
رقم: Code: 1040
Description:PF lift
motor 2 error (paper feeder) After cassette 4 is inserted, PF lift sensor 2
does not turn on within 15 s. This error is detected 5 times successively. During
driving the motor, the lift overcurrent protective monitor signal is detected
for 1 s or more 5 times successively. However, the first 1 s after motor is
turned on is excluded from detection.
Causes:Cassette
lift base elevating mechanism. PF Lift motor 2. PF Lift sensor 2. PF main PWB
Remedy:Cassette
lift base elevating mechanism Check that the cassette base can be manipulated
smoothly, if not, repair or replace.
PF Lift motor 2 1. Check that the cassette base has been ascended. 2. Check the
drive gear can rotate or they are not unusually loaded and, if necessary,
replace. 3. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. PF Lift motor 2 and PF main
PWB 4. If the wiring is disconnected, shorted or grounded, replace the wiring.
5. Replace the PF Lift motor2.
PF Lift sensor 2 1. Check that the sensor is correctly positioned. 2. Confirm
that the wiring connector is firmly connected and, if necessary, connect the
connector all the way in. PF Lift sensor 2 and PF main PWB 3. If the wiring is
disconnected, shorted or grounded, replace the wiring. 4. Replace the PF Lift
sensor 2.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper
feeder).
عطل كودي
رقم: Code: 1100
Description:PF lift
motor 1 error (large capacity feeder) After cassette 3 is inserted, PF lift
sensor 1 does not turn on within 23 s. This error is detected 5 times
successively. (Time to detect is 2 seconds at the second time and later.)
During driving the motor, the lift overcurrent protective monitor signal is
detected for 1 s or more 5 times successively. However, the first 1 s after PF
lift motor 1 is turned on is excluded from detection.
Causes:Paper
feeder lift base elevating mechanism. PF Lift motor1. PF Lift sensor1. PF main
PWB
Remedy:Paper
feeder lift base elevating mechanism Check that the cassette base can be
manipulated smoothly, if not, repair or replace.
PF Lift motor1 1. Check that the cassette base has been ascended. 2. Check the
drive gear can rotate or they are not unusually loaded and, if necessary,
replace. 3. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. PF Lift motor 1 and PF main
PWB 4. If the wiring is disconnected, shorted or grounded, replace the wiring.
5. Replace the PF lift motor1.
PF Lift sensor1 1. Check that the sensor is correctly positioned. 2. Confirm
that the wiring connector is firmly connected and, if necessary, connect the
connector all the way in. PF Lift sensor 1 and PF main PWB 3. If the wiring is
disconnected, shorted or grounded, replace the wiring. 4. Replace the PF lift
sensor1.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper
feeder).
عطل كودي
رقم: Code: 1110
Description:PF lift
motor 2 error (large capacity feeder) After cassette 4 is inserted, PF lift
sensor 2 does not turn on within 23 s. This error is detected 5 times
successively. (Time to detect is 2 seconds at the second time and later.)
During driving the motor, the lift overcurrent protective monitor signal is
detected for 1 s or more 5 times successively. However, the first 1 s after PF
lift motor 2 is turned on is excluded from detection.
Causes:Paper
feeder lift base elevating mechanism. PF Lift motor 2. PF Lift sensor2. PF main
PWB
Remedy:Paper
feeder lift base elevating mechanism Check that the cassette base can be
manipulated smoothly, if not, repair or replace.
PF Lift motor 2 1. Check that the cassette base has been ascended. 2. Check the
drive gear can rotate or they are not unusually loaded and, if necessary,
replace. 3. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. PF Lift motor 2 and PF main
PWB 4. If the wiring is disconnected, shorted or grounded, replace the wiring.
5. Replace the PF Lift motor2.
PF Lift sensor2 1. Check that the sensor is correctly positioned. 2. Confirm
that the wiring connector is firmly connected and, if necessary, connect the
connector all the way in. PF Lift sensor 2 and PF main PWB 3. If the wiring is
disconnected, shorted or grounded, replace the wiring. 4. Replace the PF Lift
sensor 2.
PF main PWB Replace the PF main PWB (Refer to the service manual for the paper
feeder).
عطل كودي
رقم: Code: 1800
Description:Paper
feeder communication error A communication error from paper feeder is detected
10 times in succession.
Causes:Paper
feeder. PF main PWB. Engine PWB
Remedy:Paper
feeder Check the wiring connection status with the main unit and, if necessary,
try connecting it again.
PF main PWB 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. PF main PWB and Engine PWB
(YC20) 2. If the wiring is disconnected, shorted or grounded, replace the
wiring. 3. Replace the PF main PWB (Refer to the service manual for the paper
feeder).
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 1900
Description:Paper
feeder EEPROM error When writing the data, read and write data does not match 4
times in succession.
Causes:PF main
PWB (EEPROM)
Remedy:PF main
PWB (EEPROM) 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. 2. Replace the PF main PWB
(Refer to the service manual for the paper feeder).
عطل كودي
رقم: Code: 2000
Description:Main
motor steady-state error After main motor is stabilized, the ready signal is at
the H level for 2 s continuously.
Causes:Main
motor. Engine PWB
Remedy:Main
motor 1. To check the motor operation execute U030 Main (main motor). 2. Check
the drive gear can rotate or they are not unusually loaded and, if necessary,
replace. 3. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Main motor and Engine PWB
(YC13) 4. If the wiring is disconnected, shorted or grounded, replace the
wiring. 5. Replace the main motor.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 2010
Description:Main
motor startup error Main motor is not stabilized within 1 s since the motor is
activated.
Causes:Main
motor. Engine PWB
Remedy:Main
motor 1. To check the motor operation execute U030 Main (main motor). 2.
Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. Main motor and Engine PWB (YC13) 3. If the
wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace the
main motor.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 2500
Description:Paper
feed motor steadystate error The rated speed signal detected the stability OFF
continuously for 2 s after the paper feed motor stabilizes.
Causes:Paper
feed motor. Engine PWB
Remedy:Paper
feed motor 1. To check the motor operation execute U030 Feed (paper feed motor).
2. Check the paper feed roller and drive gear can rotate or they are not
unusually loaded and, if necessary, replace. 3. Confirm that the wiring
connector is firmly connected and, if necessary, connect the connector all the
way in. Paper feed motor and Engine PWB (YC13) 4. If the wiring is
disconnected, shorted or grounded, replace the wiring. 5. Replace the paper
feed motor.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 2510
Description:Paper
feed motor startup error Paper feed motor is not stabilized within 1 s since
the motor is activated.
Causes:Paper
feed motor. Engine PWB
Remedy:Paper
feed motor 1. To check the motor operation execute U030 Feed (paper feed
motor). 2. Check the paper feed roller and drive gear can rotate or they are
not unusually loaded and, if necessary, replace. 3. Confirm that the wiring
connector is firmly connected and, if necessary, connect the connector all the
way in. Paper feed motor and Engine PWB (YC13) 4. If the wiring is
disconnected, shorted or grounded, replace the wiring. 5. Replace the paper
feed motor.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 2600
Description:PF drive
motor error (paper feeder) After PF drive motor is driven, the ready signal
does not turn to L within 2 s.
Causes:PF drive
motor. PF main PWB
Remedy:PF drive
motor 1. To check the feed unit operation, execute U247 2PF- Motor ON. 2. Check
the paper feed roller and drive gear can rotate or they are not unusually
loaded and, if necessary, replace. 3. Confirm that the wiring connector is
firmly connected and, if necessary, connect the connector all the way in. PF
drive motor and PF main PWB 4. If the wiring is disconnected, shorted or
grounded, replace the wiring. 5. Replace the PF drive motor.
PF main PWB Replace the PF main PWB.
عطل كودي
رقم: Code: 2610
Description:PF drive
motor error (large capacity feeder) After PF drive motor is driven, the ready
signal does not turn to L within 2 s.
Causes:PF drive
motor. PF main PWB
Remedy:PF drive
motor 1. To check the feed unit operation, execute U247 LCF- Motor ON. 2. Check
the paper feed roller and drive gear can rotate or they are not unusually
loaded and, if necessary, replace. 3. Confirm that the wiring connector is
firmly connected and, if necessary, connect the connector all the way in. PF
drive motor and PF main PWB 4. If the wiring is disconnected, shorted or
grounded, replace the wiring. 5. Replace the PF drive motor.
PF main PWB Replace the PF main PWB.
عطل كودي
رقم: Code: 3100
Description:Scanner
carriage error ON/OFF of the HP sensor doesn’t change after a prescribed pulse
passes from power supply ON.
Causes:The
scanner mirror frame is being locked after setup. Scanner motor. Home position
sensor. Engine PWB. Main PWB
Remedy:The
scanner mirror frame is being locked after setup. Check whether the scanner
mirror frame has been unlocked and unlock if necessary.
Scanner motor 1. To check the scanner motor, execute U073. 2. Move the scanner
by the hand to check whether it is unusually difficult to move. 3. Check that
the optical wire rope is not disengaged and engage the wire. 4. Confirm that
the wiring connector is firmly connected and, if necessary, connect the
connector all the way in. Scanner motor and Engine PWB (YC34) Engine PWB (YC37)
and Main PWB (YC65) 5. If the wiring is disconnected, shorted or grounded,
replace the wiring. 6. Replace the scanner motor.
Home position sensor 1. Check that the sensor is correctly positioned. 2.
Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. Home position sensor and Engine PWB
(YC34) 3. Replace the home position sensor.
Engine PWB Replace the Engine PWB and execute U411.
Main PWB Replace the main PWB.
عطل كودي
رقم: Code: 3200
Description:LED lamp
startup error The white reference data acquired by lighting the lamp at the
initial operation is at the specified value or less. (Over 2 LED lamps do not
light.)
Causes:LED PWB.
Engine PWB. Main PWB
Remedy:LED PWB
Check if the LED lamp lights by executing [CCD] at U061. If it does not light,
replace the lamp unit and execute [Table(ChartA)] at U411.
Engine PWB Replace the engine PWB.
Main PWB Replace the main PWB.
عطل كودي
رقم: Code: 3210
Description:CIS lamp
error When input value at the time of CIS illumination does not exceed the
threshold value between 5 s.
Causes:CIS.
DPSHD PWB. DP relay PWB
Remedy:CIS 1.
Execute U906 Separating Operation Release. 2. Execute CIS of U061 lamp check.
3. Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. CIS and DPSHD PWB (YC2) DPSHD PWB (YC3)
and DP relay PWB (YC2) 4. If the wiring is disconnected, shorted or grounded,
replace the wiring. 5. Replace the CIS and execute U091 and U411.
DPSHD PWB Replace the DPSHD PWB.
DP relay PWB Replace the DP relay PWB.
عطل كودي
رقم: Code: 3300
Description:Optical
system (AGC) error When the value of a gain becomes more than FF or 89 or less
at least one at the AGC processing instruction execution time for CCD lamps.
Causes:LED lamp
PWB. CCD PWB. Engine PWB. Main PWB
Remedy:LED lamp
PWB 1. To check the lamp, execute U061 CCD. 2. Confirm that the wiring
connector is firmly connected and, if necessary, connect the connector all the
way in. LED lamp PWB and CCD PWB (YC2) CCD PWB (YC1) and Engine PWB (YC29)
Engine PWB (YC3) and Main PWB (YC64) 3. If the wiring is disconnected, shorted
or grounded, replace the wiring. 4. If the LED lamp won’t light, replace the
LED PWB and execut U411.
CCD PWB Replace the ISU and execute U411.
Engine PWB Replace the Engine PWB and execute U411.
Main PWB Replace the main PWB.
عطل كودي
رقم: Code: 3310
Description:CIS AGC
error One of the gains is FF during the CCD lamp AGC is being processed.
Causes:CIS.
DPSHD PWB
Remedy:CIS 1.
Execute U906 Separating Operation Release. 2. To check the lamp, execute U061
CIS. 3. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. DP CIS and DPSHD PWB (YC2)
DPSHD PWB (YC3) and DP relay PWB (YC2) 4. If the wiring is disconnected,
shorted or grounded, replace the wiring. 5. Replace the CIS and execute U091
and U411.
DPSHD PWB Replace the DPSHD PWB.
عطل كودي
رقم: Code: 3500
Description:Communication
error between scanner and ASIC A wrong read-back value.
Causes:Engine
PWB. Main PWB
Remedy:Engine
PWB 1. Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. Engine PWB (YC3) and Main PWB (YC64) 2.
If the wiring is disconnected, shorted or grounded, replace the wiring. 3.
Replace the Engine PWB and execute U411.
Main PWB Replace the main PWB.
عطل كودي
رقم: Code: 3600
Description:Scanner
sequence error
Causes:Engine
PWB
Remedy:1.
Execute U021 memory initializing. 2. Replace the Engine PWB and execute U411.
عطل كودي
رقم: Code: 3800
Description:AFE
error When writing the data, read and write data does not match 3 times in
succession.
Causes:Engine
PWB. CCD PWB
Remedy:Engine
PWB 1. Confirm that the FCC wiring connector is not distorted and connect the
FCC wiring all the way in. CCD PWB (YC1) and Engine PWB (YC29) 2. If the FCC
wiring is disconnected, replace the FCC wiring. 3. Replace the Engine PWB and
execute U411.
CCD PWB Replace the ISU and execute U411.
عطل كودي
رقم: Code: 3900
Description:Backup
memory read/write error (Engine PWB) Read and write data does not match.
Causes:Backup
memory (Engine PWB PWB)
Remedy:1. Turn
the main power switch off and after 5 seconds, turn it on. 2. Replace the
Engine PWB and execute U411.
عطل كودي
رقم: Code: 4001
Description:Polygon
motor synchronization error After polygon motor is driven, the ready signal
does not turn to L within 10 s.
Causes:Polygon
motor (Laser scanner unit). Engine PWB.
Remedy:Polygon
motor (Laser scanner unit) 1. Confirm that the wiring connector is firmly
connected and, if necessary, connect the connector all the way in. Polygon
motor and Engine PWB (YC28) 2. If the wiring is disconnected, shorted or
grounded, replace the wiring. 3. Replace the laser scanner unit.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 4011
Description:Polygon
motor steady-state error After Polygon motor is stabilized, the ready signal is
at the H level for 1 s continuously.
Causes:Polygon
motor (Laser scanner unit). Engine PWB
Remedy:Polygon
motor (Laser scanner unit) 1. Confirm that the wiring connector is firmly
connected and, if necessary, connect the connector all the way in. Polygon
motor and Engine PWB (YC5) 2. If the wiring is disconnected, shorted or
grounded, replace the wiring. 3. Replace the laser scanner unit.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 4101
Description:BD
initialization error After Polygon motor is driven, the BD signal is not
detected for 1 s.
Causes:PD PWB
(Laser scanner unit). Engine PWB
Remedy:PD PWB
(Laser scanner unit) 1. Confirm that the FCC wiring connector is not distorted
and connect the FCC wiring all the way in. APC PWB (YC1) and Engine PWB (YC4)
2. If the FCC wiring is disconnected, replace the FCC wiring. 3. Replace the
laser scanner unit.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 4201
Description:BD
steady-state error The BD signal is not detected.
Causes:PD PWB
(Laser scanner unit). Engine PWB
Remedy:PD PWB
(Laser scanner unit) 1. Confirm that the FCC wiring connector is not distorted
and connect the FCC wiring all the way in. APC PWB (YC1) and Engine PWB (YC5)
2. If the FCC wiring is disconnected, shorted or grounded, replace the FCC
wiring. 3. Replace the laser scanner unit.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 4700
Description:VIDEO_ASIC
device error Communication with the video ASIC has failed 10 times
successively.
Causes:Engine
PWB. Main PWB
Remedy:Engine
PWB 1. Unplug the power cord from the wall outlet, and wait five seconds. Then
plug in the power cord and then turn on the power switch. 2. Check that the
connectors on the engine PWB are properly connected, and if not, re-connect
them. 3. Replace the engine PWB.
Main PWB 1. Check that the connectors on the main PWB are properly connected,
and if not, re-connect them. 2. Replace the main PWB.
عطل كودي
رقم: Code: 5101
Description:Main
high-voltage error Measure the inflowing current when Vpp is varied in 3 steps
and verify if the difference of the currents of 0 and step 2 is less than 5.
Causes:Drum
unit. Charger roller unit. High voltage PWB. Engine PWB
Remedy:Drum
unit 1. Confirm that the drum or the drum screw can rotate. 2. If it won’t
rotate, replace the drum unit. 3. Check that the discharger lamp is properly
connected.
Charger roller unit 1. Check that the high-voltage contacts are not distorted
or adhered with foreign objects. 2. Reinstall the chrager roller unit.Or,
replace the charger roller unit.
High voltage PWB 1. Confirm that the wiring connector is firmly connected and,
if necessary, connect the connector all the way in. High voltage PWB (CN1) and
Engine PWB (YC19) 2. If the FCC wiring is disconnected, shorted or grounded,
replace the FCC wiring. 3. Replace the High voltage PWB.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 6020
Description:Abnormally
high fuser thermistor 2 temperature Input from fuser thermistor 2 is abnormal
value continuously for 1 s.
Causes:Fuser
unit. Fuser thermistor 2. Engine PWB
Remedy:Fuser
unit 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Fuser thermistor 2 and Engine
PWB (YC9) 2. If the wiring is disconnected, shorted or grounded, replace the
wiring. 3. If the I/F connector pins of the fuser unit and the main unit are
deformed owing to foreign matters, such as paper dusts, replace the connectors
or the units including the connectors.
Fuser thermistor 2 Replace the Fuser unit.
Engine PWB Replace the engine PWB.
عطل كودي
رقم: Code: 6030
Description:Broken
fuser thermistor 2 wire The center thermistor A/D value is 4/1024 bit (19°C) or
less, even if the main heater is turned on 10[sec] in succession.
Causes:Fuser
unit. Fuser thermistor 2. Engine PWB
Remedy:Fuser
unit 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Fuser thermistor 2 and Engine
PWB (YC9) 2. If the wiring is disconnected, shorted or grounded, replace the
wiring. 3. If the I/F connector pins of the fuser unit and the main unit are
deformed owing to foreign matters, such as paper dusts, replace the connectors
or the units including the connectors.
Fuser thermistor 2 Replace the Fuser unit.
Engine PWB Replace the engine PWB.
عطل كودي
رقم: Code: 6200
Description:Broken fuser
edge heater wire Even if 50 seconds pass after a warm-up start, when it will
not be in a stable state. When the difference in temperature 4 seconds and 12
seconds after heater lighting is less than 45 °C. Even if 8 seconds pass during
test mode operation, when change of AD is less than three.
Causes:Fuser
unit. Fuser thermostat. Fuser heater. Powe source PWB. Engine PWB
Remedy:Fuser
unit 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Power source PWB (YC7) and
Engine PWB (YC10) 2. If the wiring is disconnected, shorted or grounded,
replace the wiring. 3. If the I/F connector pins of the fuser unit and the main
unit are deformed owing to foreign matters, such as paper dusts, replace the
connectors or the units including the connectors.
Fuser thermostat Fuser heater. Replace the Fuser unit.
Powe source PWB Replace the power source PWB.
Engine PWB Replace the engine PWB.
عطل كودي
رقم: Code: 6220
Description:Abnormally
high fuser edge thermistor temperature Input from fuser thermistor 1 is
abnormal value continuously for 1 s.
Causes:Fuser
unit. Fuser thermistor 1. Engine PWB
Remedy:Fuser
unit 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Fuser thermistor 1 and Engine
PWB (YC9) 2. If the wiring is disconnected, shorted or grounded, replace the
wiring. 3. If the I/F connector pins of the fuser unit and the main unit are
deformed owing to foreign matters, such as paper dusts, replace the connectors
or the units including the connectors.
Fuser thermistor 1 Replace the Fuser unit.
Engine PWB Replace the engine PWB.
عطل كودي
رقم: Code: 6230
Description:Broken
fuser edge thermistor wire A/D value of the fuser thermistor 1 exceeds 252 bit
(10 °C) continuously for 4 s during warming up.
Causes:Fuser
unit. Fuser thermistor 1. Engine PWB
Remedy:Fuser
unit 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Fuser thermistor 1 and Engine
PWB (YC9) 2. If the wiring is disconnected, shorted or grounded, replace the
wiring. 3. If the I/F connector pins of the fuser unit and the main unit are
deformed owing to foreign matters, such as paper dusts, replace the connectors
or the units including the connectors.
Fuser thermistor 1 Replace the Fuser unit.
Engine PWB Replace the engine PWB.
عطل كودي
رقم: Code: 6250
Description:Abnormally
low fuser edge thermistor temperature When the detection temperature of the
fixing thermistor 1 is falling target temperature by 100 °C or more for 1
second after secondary stable temperature attainment.
Causes:Fuser
unit. Fuser thermostat. Fuser heater. Engine PWB
Remedy:Fuser
unit 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Fuser thermistor 1 and Engine
PWB (YC9) 2. If the wiring is disconnected, shorted or grounded, replace the
wiring. 3. If the I/F connector pins of the fuser unit and the main unit are
deformed owing to foreign matters, such as paper dusts, replace the connectors
or the units including the connectors.
Fuser thermostat Fuser heater. Replace the Fuser unit.
Engine PWB Replace the engine PWB.
عطل كودي
رقم: Code: 6400
Description:Zero-cross
signal error While fuser heater ON/OFF control is performed, the zerocross
signal is not input within 3 s.
Causes:Fuser
unit
Remedy:1.
Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. Power source PWB (YC7) and engine PWB
(YC10) 2. If the wiring is disconnected, shorted or grounded, replace the
wiring. 3. Replace the fuser heater PWB.
عطل كودي
رقم: Code: 6910
Description:Engine
software ready error The device won’t engage in ready state in 60 minutes after
warming-up has began. (A previous timeout process has not been cancelled.)
Causes:Engine
PWB
Remedy:1. Turn
the main power switch off and after 5 seconds, turn it on. 2. Reinstall the
engine software. 3. Replace the engine PWB.
عطل كودي
رقم: Code: 7200
Description:Broken
outer temperature sensor 2 wire The sensor input sampling is greater than 818.
Causes:APC PWB.
Engine PWB
Remedy:APC PWB
1. Confirm External Temp is displayed by U139 temperature and humidity. 2.
Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. APC PWB (YC1) and Engine PWB (YC4) 3. If
the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace
the BD PWB.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 7210
Description:Short-circuited
outer temperature sensor The temperature sensor input sampling is less than
353.
Causes:APC PWB.
Engine PWB
Remedy:APC PWB
1. Confirm External Temp is displayed by U139 temperature and humidity. 2.
Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. APC PWB (YC1) and Engine PWB (YC4) 3. If
the wiring is disconnected, shorted or grounded, replace the wiring. 4. Replace
the BD PWB.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 7800
Description:Broken
outer temperature sensor wire The temperature sensor input sampling is more
than 244.
Causes:Thermistor
PWB. Engine PWB
Remedy:Thermistor
PWB 1. Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. Thermistor PWB and Engine PWB (YC12). 2.
If the wiring is disconnected, shorted or grounded, replace the wiring. 3.
Replace the thermistor PWB.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 7810
Description:Short-circuited
external thermistor wire The temperature sensor input sampling is less than 11.
Causes:Thermistor
PWB, Engine PWB
Remedy:Thermistor
PWB 1. Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. Thermistor PWB and Engine PWB (YC6) 2. If
the wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace
the thermistor PWB.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 7901
Description:Drum
EEPROM error No response is issued from the device in reading/writing for 5 ms
or more and this problem is repeated five times successively. Mismatch of
reading data from two locations occurs 8 times successively. Mismatch between
writing data and reading data occurs 8 times successively.
Causes:Drum
unit. Engine PWB
Remedy:Drum
unit 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Durm unit and Drum relay PWB
(YC2) Drum relay PWB (YC1) and Engine PWB (YC12) 2. If the wiring is disconnected,
shorted or grounded, replace the wiring. 3. Replace the Drum unit.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 7911
Description:Developer
unit EEPROM error No response is issued from the device in reading/writing for
5 ms or more and this problem is repeated five times successively. Mismatch of
reading data from two locations occurs 8 times successively. Mismatch between
writing data and reading data occurs 8 times successively.
Causes:Developer
unit. Engine PWB
Remedy:Developer
unit 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Developer unit and developer
relay PWB (YC1) Developer relay PWB (YC2) and Engine PWB (YC11) 2. If the
wiring is disconnected, shorted or grounded, replace the wiring. 3. Replace the
Developer unit.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 8010
Description:Punch
motor 1 error When the punch motor is driven, punch home position sensor does
not turn on within 200 ms.
Causes:Punch
motor. Punch home position sensor. Punch PWB. DF main PWB
Remedy:Punch
motor 1. Execute U240 Motor – Punch to check the finisher operation. 2.
Manipulate the punch up and down to check it can smoothly move up and down. 3.
Check that the drive from the motor reaches the punch cam. 4. Confirm that the
wiring connector is firmly connected and, if necessary, connect the connector
all the way in. Punch motor and Punch PWB (YC4) 5. If the wiring is
disconnected, shorted or grounded, replace the wiring. 6. Replace the punch
motor.
Punch home position sensor 1. Execute U241 Punch – Punch HP to check the
finisher switch. 2. Check that the sensor and its mounting bracket are
correctly positioned. 3. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. Punch home position
sensor and Punch PWB (YC8) 4. Replace the Punch home position sensor.
Punch PWB 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Punch PWB (YC1) and DF main
PWB (YC7) (3000-sheet finisher) Punch PWB (YC1) and DF main PWB (YC8)
(1000-sheet finisher) 2. Replace the punch PWB.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8020
Description:Punch
motor 2 error Home position is not obtained in 3 s after home position is
initialized or in standby.
Causes:Punch
motor. Punch PWB. DF main PWB
Remedy:Punch
motor 1. Execute U240 Motor – Punch to check the finisher operation. 2.
Manipulate the punch up and down to check it can smoothly move up and down. 3.
Check that the drive from the motor reaches the punch cam. 4. Confirm that the
wiring connector is firmly connected and, if necessary, connect the connector
all the way in. Punch motor and Punch PWB (YC4) 5. If the wiring is
disconnected, shorted or grounded, replace the wiring. 6. Replace the punch
motor.
Punch PWB 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Punch PWB (YC1) and DF main
PWB (YC7)(3000-sheet finisher) Punch PWB (YC1) and DF main PWB (YC8)(1000-sheet
finisher) 2. Replace the punch PWB.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8030
Description:Punch
motor 3 error Home position does not turn from On to Off in 50 ms after home
position has been initialized.
Causes:Punch
motor. Punch PWB. DF main PWB
Remedy:Punch
motor 1. Execute U240 Motor – Punch to check the finisher operation. 2.
Manipulate the punch up and down to check it can smoothly move up and down. 3.
Check that the drive from the motor reaches the punch cam. 4. Confirm that the
wiring connector is firmly connected and, if necessary, connect the connector
all the way in. Punch motor and Punch PWB (YC4) 5. If the wiring is
disconnected, shorted or grounded, replace the wiring. 6. Replace the punch
motor.
Punch PWB 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Punch PWB (YC1) and DF main
PWB (YC7) (3000-sheet finisher) Punch PWB (YC1) and DF main PWB (YC8)
(1000-sheet finisher) 2. Replace the punch PWB.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8090
Description:DF
paddle motor error When the DF paddle motor is driven, DF paddle sensor does
not turn on within 1 s.
Causes:DF
paddle motor. DF paddle sensor. DF main PWB
Remedy:DF
paddle motor 1. Execute U240 Motor – Beat to check the finisher operation. 2.
Check that the paddle can rotate. 3. Check that the drive from the motor
reaches the paddle. 4. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. DF paddle motor and DF
main PWB (YC15) (3000-sheet finisher) DF paddle motor and DF main PWB (YC11)
(1000-sheet finisher) 5. If the wiring is disconnected, shorted or grounded,
replace the wiring. 6. Replace the DF paddle motor.
DF paddle sensor 1. Execute U241 Finisher – Lead Paddle to check the finisher
switch. 2. Check that the sensor and its mounting bracket are correctly
positioned. 3. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. DF paddle sensor and DF main
PWB (YC22) (3000-sheet finisher) DF paddle sensor and DF main PWB (YC20)
(1000-sheet finisher) 4. Replace the DF paddle sensor.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8100
Description:DF eject
release motor error When the DF eject release motor is driven, DF bundle
discharge sensor does not turn on within 1 s.
Causes:DF eject
release motor DF bundle discharge unit sensor. DF bundle discharge unit sensor.
DF main PWB
Remedy:DF eject
release motor DF bundle discharge unit sensor 1. Execute U240 Motor – Eject
Unlock (Full) to check the finisher operation. 2. Check that the eject guide of
the process tray is opened and, if not, correct the guide. 3. Check that the
drive from the motor reaches the eject guide. 4. Confirm that the wiring
connector is firmly connected and, if necessary, connect the connector all the
way in. DF bundle discharge unit sensor and DF main PWB (YC22)(3000-sheet
finisher) DF bundle discharge unit sensor and DF main PWB (YC20)(1000-sheet
finisher) 5. If the wiring is disconnected, shorted or grounded, replace the
wiring. 6. Replace the DF eject release motor.
DF bundle discharge unit sensor 1. Execute U241 Finisher – Bundle Eject HP to
check the finisher switch. 2. Check that the sensor and its mounting bracket
are correctly positioned. 3. Confirm that the wiring connector is firmly
connected and, if necessary, connect the connector all the way in. DF bundle
discharge unit sensor and DF main PWB (YC22)(3000-sheet finisher) DF bundle
discharge unit sensor and DF main PWB (YC20)(1000-sheet finisher) 4. Replace
the DF bundle eject unit sensor.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8110
Description:DF shift
motor 1 error (3000-sheet finisher) DF shift sensor 1 won’t turn on when it has
travelled 160 mm after DF shift motor 1 is driven.
Causes:DF shift
motor 1 front. DF shift sensor 1 front. DF main PWB
Remedy:DF shift
motor 1 front 1. Execute U240 Motor – Sort Test to check the finisher operation.
2. Manipulate the front shift guide back and forth to check it is smoothly
operable. 3. Check that the drive from the motor reaches the front shift guide.
4. Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. DF shift motor 1 front and DF main PWB
(YC14) 5. If the wiring is disconnected, shorted or grounded, replace the
wiring. 6. Replace the DF shift motor 1 front.
DF shift sensor 1 front 1. Execute U241 Finisher – Shift Front HP to check the
finisher switch. 2. Check that the sensor and its mounting bracket are
correctly positioned. 3. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. DF shift sensor 1
front and DF main PWB (YC23) 4. Replace the DF shift sensor 1 front.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8120
Description:DF shift
motor 2 error (3000-sheet finisher) DF shift sensor 2 won’t turn on when it has
travelled 160 mm after DF shift motor 2 is driven.
Causes:DF shift
motor 2 rear. DF shift sensor 2 rear. DF main PWB
Remedy:DF shift
motor 2 rear 1. Execute U240 Motor – Sort Test to check the finisher operation.
2. Manipulate the rear shift guide back and forth to check it is smoothly
operable. 3. Check that the drive from the motor reaches the rear shift guide.
4. Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. DF shift motor 2 rear and DF main PWB
(YC14) 5. If the wiring is disconnected, shorted or grounded, replace the
wiring. 6. Replace the DF shift motor 2 rear.
DF shift sensor 2 rear 1. Execute U241 Finisher – Shift Tail HP to check the
finisher switch. 2. Check that the sensor and its mounting bracket are
correctly positioned. 3. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. DF shift sensor 2 rear
and DF main PWB (YC23) 4. Replace the DF shift set sensor2 rear.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8130
Description:DF shift
release motor error (3000-sheet finisher) When the DF shift release motor is
driven, DF shift release sensor does not turn on within 1 s.
Causes:DF shift
release motor. DF shift release sensor. DF main PWB
Remedy:DF shift
release motor 1. Check that cancelling the maintenance mode after executing
U240 Motor – Sort for the finisher operation check lets the rear and forth
cursors returns to the home position. 2. Manipulate the front and rear shift
guide to check it is smoothly operable. 3. Check that the drive from the motor
reaches the shift guide front and rear. 4. Confirm that the wiring connector is
firmly connected and, if necessary, connect the connector all the way in. DF
shift release motor and DF main PWB (YC14) 5. If the wiring is disconnected,
shorted or grounded, replace the wiring. 6. Replace the DF shift release motor.
DF shift release sensor 1. Execute U241 Finisher – Shift Unlock HP to check the
finisher switch. 2. Check that the sensor and its mounting bracket are
correctly positioned. 3. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. DF shift release
sensor and DF main PWB (YC23) 4. Replace the DF shift release sensor.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8140
Description:DF tray
error 1 When the main tray has ascended, DF tray sensor 1 or DF tray upper
surface sensor does not turn on within 30 s.
Causes:DF tray
motor. DF tray sensor 1 DF tray upper surface sensor. DF main PWB
Remedy:DF tray
motor 1. Execute U240 Motor – Tray to check the finisher operation. 2.
Manipulate the main tray up and down to check it is smoothly operable. 3. Check
that the drive from the motor reaches the main tray. 4. Confirm that the wiring
connector is firmly connected and, if necessary, connect the connector all the
way in. DF tray motor and DF Main PWB(YC16) (3000-sheet finisher) DF tray motor
and DF Main PWB(YC14) (1000-sheet finisher) 5. If the wiring is disconnected,
shorted or grounded, replace the wiring. 6. Replace the DF tray motor.
DF tray sensor 1 DF tray upper surface sensor 1. Execute U241 Finisher – Tray
U-Limit, Tray Top to check the finisher switch. 2. Check that the sensor and
its mounting bracket are correctly positioned. 3. Confirm that the wiring
connector is firmly connected and, if necessary, connect the connector all the
way in. DF tray sensor 1 and DF Main PWB(YC22) (3000-sheet finisher) DF tray
upper surface sensor and DF Main PWB(YC21,YC13) (3000-sheet finisher) DF tray
sensor 1 and DF main PWB (YC20) (1000-sheet finisher) DF tray upper surface
sensor and DF main PWB (YC18) (1000-sheet finisher) 4. Replace the DF tray
sensor 1 or DF tray upper surface sensor.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8150
Description:DF tray
error 2 When the main tray has descended, DF tray sensor 1 or DF tray upper
surface sensor does not turn off within 5 s.
Causes:DF tray
motor. DF tray sensor 1 DF tray upper surface sensor. DF main PWB
Remedy:DF tray
motor 1. Execute U240 Motor – Tray to check the finisher operation. 2.
Manipulate the main tray up and down to check it is smoothly operable. 3. Check
that the drive from the motor reaches the main tray. 4. Confirm that the wiring
connector is firmly connected and, if necessary, connect the connector all the
way in. DF tray motor and DF main PWB (YC16) (3000-sheet finisher) DF tray
motor and DF main PWB (YC14) (1000-sheet finisher) 5. If the wiring is disconnected,
shorted or grounded, replace the wiring. 6. Replace the DF tray motor.
DF tray sensor 1 DF tray upper surface sensor 1. Execute U241 Finisher – Tray
U-Limit, Tray Top to check the finisher switch. 2. Check that the sensor and
its mounting bracket are correctly positioned. 3. Confirm that the wiring
connector is firmly connected and, if necessary, connect the connector all the
way in. DF tray sensor 1 and DF main PWB (YC22) (3000-sheet finisher) DF tray
upper surface sensor and DF main PWB (YC21,YC13) (3000-sheet finisher) DF tray
sensor 1 and DF main PWB (YC20) (1000-sheet finisher) DF tray upper surface
sensor and DF main PWB (YC18) (1000-sheet finisher) 4. Replace the DF tray
sensor 1 or DF tray upper surface sensor.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8160
Description:DF tray
error 3 When the main tray has descended, DF tray sensor 4 does not turn on
within 20 s.
Causes:DF tray
motor. DF tray sensor 4. DF main PWB
Remedy:DF tray
motor 1. Execute U240 Motor – Tray to check the finisher operation. 2.
Manipulate the main tray up and down to check it is smoothly operable. 3. Check
that the drive from the motor reaches the main tray. 4. Confirm that the wiring
connector is firmly connected and, if necessary, connect the connector all the
way in. DF tray motor and DF main PWB (YC16) (3000-sheet finisher) DF tray
motor and DF main PWB (YC14) (1000-sheet finisher) 5. If the wiring is
disconnected, shorted or grounded, replace the wiring. 6. Replace the DF tray
motor.
DF tray sensor 4 1. Execute U241 Finisher – Tray Middle to check the finisher
switch. 2. Check that the sensor and its mounting bracket are correctly
positioned. 3. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. DF tray sensor 4 and DF main
PWB (YC23) (3000-sheet finisher) DF tray sensor 4 and DF main PWB (YC20)
(1000-sheet finisher) 4. Replace the DF tray sensor 4.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8170
Description:DF side
registration motor 1 error 1 When initial operation, DF side registration
sensor 1 does not turn on within 3 s.
Causes:DF side
registration motor 1. DF side registration sensor 1. DF main PWB
Remedy:DF side
registration motor 1 1. Execute U240 Motor – Width Test to check the finisher
operation. 2. Manipulate the front side registration guide to check it is
smoothly operable. 3. Check that the drive from the motor reaches the front
side registration guide. 4. Confirm that the wiring connector is firmly
connected and, if necessary, connect the connector all the way in. DF side
registration motor 1 and DF main PWB (YC15) (3000-sheet finisher) DF side
registration motor 1 and DF main PWB (YC11) (1000-sheet finisher) 5. If the
wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the
DF side registration motor 1.
DF side registration sensor 1 1. Execute U241 Finisher – Width Front to check
the finisher switch. 2. Check that the sensor and its mounting bracket are
correctly positioned. 3. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. DF side registration
sensor 1. and DF main PWB (YC22) (3000-sheet finisher) DF side registration
sensor 1. and DF main PWB (YC20) (1000-sheet finisher) 4. Replace the DF side
registration sensor 1.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8180
Description:DF side
registration motor 1 error 2 JAM6810 ( jam in front of width alignment) is
detected twice
Causes:DF side
registration motor 1. DF side registration sensor 1. DF main PWB
Remedy:DF side
registration motor 1 1. Execute U240 Motor – Width Test to check the finisher
operation. 2. Manipulate the front side registration guide back and forth to
check it is smoothly operable. 3. Check that the drive from the motor reaches
the front side registration guide. 4. Confirm that the wiring connector is
firmly connected and, if necessary, connect the connector all the way in. DF
side registration motor 1 and DF main PWB (YC15) (3000-sheet finisher) DF side
registration motor 1 and DF main PWB (YC11) (1000-sheet finisher) 5. If the
wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the
DF side registration motor 1.
DF side registration sensor 1. 1. Execute U241 Finisher – Width Front to check
the finisher switch. 2. Check that the sensor and its mounting bracket are
correctly positioned. 3. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. DF side registration
sensor 1 and DF main PWB (YC22) (3000-sheet finisher) DF side registration
sensor 1 and DF main PWB (YC20) (1000-sheet finisher) 4. If the wiring is
disconnected, shorted or grounded, replace the wiring. 5. Replace the DF side
registration sensor 1.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8190
Description:DF side
registration motor 2 error 1 When initial operation, DF side registration
sensor 2 does not turn on within 3 s.
Causes:DF side
registration motor 2. DF side registration sensor 2. DF main PWB
Remedy:DF side
registration motor 2 1. Execute U240 Motor – Width Test to check the finisher
operation. 2. Manipulate the rear side registration guide back and forth to
check it is smoothly operable. 3. Check that the drive from the motor reaches
the rear side registration guide. 4. Confirm that the wiring connector is
firmly connected and, if necessary, connect the connector all the way in. DF
side registration motor 2 and DF main PWB (YC15) (3000-sheet finisher) DF side
registration motor 2 and DF main PWB (YC11) (1000-sheet finisher) 5. If the
wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the
DF side registration motor 2.
DF side registration sensor 2 1. Execute U241 Finisher – Width tail HP to check
the finisher switch. 2. Check that the sensor and its mounting bracket are
correctly positioned. 3. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. DF side registration
sensor 2 and DF main PWB (YC22) (3000-sheet finisher) DF side registration
sensor 2 and DF main PWB (YC20) (1000-sheet finisher) 4. Replace the DF side
registration sensor 2.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8200
Description:DF side
registration motor 2 error 2 JAM6910 ( jam in rear of width alignment) is
detected twice
Causes:DF side
registration motor 2. DF side registration sensor 2. DF main PWB
Remedy:DF side
registration motor 2 1. Execute U240 Motor – Width Test to check the finisher
operation. 2. Manipulate the rear side registration guide back and forth to
check it is smoothly operable. 3. Check that the drive from the motor reaches
the rear side registration guide. 4. Confirm that the wiring connector is
firmly connected and, if necessary, connect the connector all the way in. DF
side registration motor 2 and DF main PWB (YC15) (3000-sheet finisher) DF side
registration motor 2 and DF main PWB (YC11) (1000-sheet finisher) 5. If the
wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the
DF side registration motor 2.
DF side registration sensor 2 1. Execute U241 Finisher – Width tail HP to check
the finisher switch. 2. Check that the sensor and its mounting bracket are
correctly positioned. 3. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. DF side registration
sensor 2 and DF main PWB (YC22) (3000-sheet finisher) DF side registration
sensor 2 and DF main PWB (YC20) (1000-sheet finisher) 4. Replace the DF side
registration sensor 2.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8210
Description:DF slide
motor error When initial operation, DF staple sensor does not turn on within 3
s.
Causes:DF slide
motor. DF staple sensor. DF main PWB
Remedy:DF slide
motor 1. Execute U240 Motor – Staple Move to check the finisher operation. 2.
Manipulate the staple unit back and forth to check it is smoothly operable. 3.
Check that the drive from the motor reaches the staple unit. 4. Confirm that
the wiring connector is firmly connected and, if necessary, connect the
connector all the way in. DF slide motor and DF main PWB (YC12) (3000-sheet
finisher) DF slide motor and DF main PWB (YC10) (1000-sheet finisher) 5. If the
wiring is disconnected, shorted or grounded, replace the wiring.
DF staple sensor 1. Execute U241 Finisher – Width Staple HP to check the
finisher switch. 2. Check that the sensor and its mounting bracket are
correctly positioned. 3. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. DF staple sensor and
DF main PWB (YC22) (3000-sheet finisher) DF staple sensor and DF main PWB
(YC20) (1000-sheet finisher) 4. If the wiring is disconnected, shorted or
grounded, replace the wiring. 5. Replace the DF staple sensor.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8230
Description:DF staple
motor error 1 Staple JAM (DF) has been detected twice in a row. (The second JAM
detection condition fullfilled with the home position did not detected in 600
ms after the motor was driven.)
Causes:DF
staple motor. DF staple sensor. DF main PWB
Remedy:DF
staple motor 1. Remove the staple unit and check that stapling is possible
without a jam. 2. Confirm that the FCC wiring connector is not distorted and
connect the FCC wiring all the way in. Staple unit and DF main PWB (YC17)
(3000-sheet finisher) Staple unit and DF main PWB (YC11) (1000-sheet finisher)
3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4.
Replace the staple unit. (Refer to the service manual for the document
finisher).
DF staple sensor Replace the staple unit.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8240
Description:DF
staple motor error 2 (3000-sheet finisher) Staple JAM (DF) has been detected
twice in a row. (The second JAM detection condition fullfilled with a lock
detection signal maintained 1 V for 500 ms continuously, while the stapler
motor was driven.)
Causes:DF
staple motor. DF main PWB
Remedy:DF
staple motor 1. Remove the staple unit and check that stapling is possible
without a jam. 2. Confirm that the FCC wiring connector is not distorted and
connect the FCC wiring all the way in. Staple unit and DF main PWB (YC17)
(3000-sheet finisher) Staple unit and DF main PWB (YC11) (1000-sheet finisher)
3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4.
Replace the staple unit. (Refer to the service manual for the document
finisher).
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8250
Description:Main
tray error 4 In case the lock signal is 0.7V or less for 10 s in succession
during the DF tray motor drive. (35/40 ppm model only)
Causes:DF tray
motor. DF main PWB
Remedy:DF tray
motor 1. Execute [Motor] > [Tray] in U240 Checking the operation of the
finisher. 2. Check if the main tray can be moved up and down manually without
getting caught. 3. Check if the motor drive is delivered to the main tray. 4.
Confirm that the wiring connector is firmly connected, and if necessary,
connect the connector all the way in. DF tray motor – DF main PWB(YC11) 5. If
the wiring is disconnected, short-circuited or has a ground fault, replace the
wire. 6. Replace the DF tray motor.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8260
Description:DF
middle motor error When the DF middle motor is driven, DF paddle sensor does
not turn on within 1s.
Causes:DF
middle motor. DF paddle sensor. DF main PWB
Remedy:DF
middle motor 1. Execute U240 Motor – Middle(L) to check the finisher operation.
2. Check that the drive from the motor reaches the middle roller. 3. Confirm
that the wiring connector is firmly connected and, if necessary, connect the
connector all the way in. DF middle motor and DF main PWB (YC12) 4. If the wiring
is disconnected, shorted or grounded, replace the wiring. 5. Replace the DF
middle motor.
DF paddle sensor 1. Execute U241 Finisher – Lead Paddle to check the finisher
switch. 2. Check that the sensor and its mounting bracket are correctly
positioned. 3. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. DF paddle sensor and DF main
PWB (YC19) 4. Replace the DF paddle sensor.
DF main PWB Replace the DF main PWB.
عطل كودي
رقم: Code: 8410
Description:Punch
slide motor error 1 The punch slide sensor won’t turn On when home position has
been moved by 30 mm.
Causes:Punch
slide motor. Punch slide sensor. Punch PWB. DF main PWB
Remedy:Punch
slide motor 1. Execute U240 Booklet – Punch Move to check the finisher
operation. 2. Manipulate the punch slide part of the punch unit back and forth
to check it can smoothly move. 3. Check that the drive from the motor reaches
punch part. 4. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Punch slide motor and Punch
PWB (YC3) 5. If the wiring is disconnected, shorted or grounded, replace the
wiring. 6. Replace the punch slide motor.
Punch slide sensor 1. Execute U241 Punch – Punch HP to check the finisher switch.
2. Check that the sensor and its mounting bracket are correctly positioned. 3.
Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. Punch slide sensor and Punch PWB (YC6) 4.
Replace the punch slide sensor.
Punch PWB 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Punch PWB (YC1) and DF main
PWB (YC7) (3000-sheet finisher) Punch PWB (YC1) and DF main PWB (YC8)
(1000-sheet finisher) 2. Replace the punch PWB.
DF main PWB Replace the DF main PWB
عطل كودي
رقم: Code: 8420
Description:Punch
slide motor error 2 In detection of paper edges, the paper edge cannot be
detected in 30 mm move
Causes:Punch
slide motor. Punch paper edge sensor 1,2. Punch PWB. DF main PWB
Remedy:Punch
slide motor 1. Execute U240 Booklet – Punch Move to check the finisher
operation. 2. Manipulate the punch slide part of the punch unit back and forth
to check it can smoothly move. 3. Check that the drive from the motor reaches
punch part. 4. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Punch slide motor and Punch
PWB (YC3) 5. If the wiring is disconnected, shorted or grounded, replace the
wiring. 6. Replace the punch slide motor.
Punch paper edge sensor 1,2 1. Execute U241 Punch – Edge Face 1,2,3,4 to check
the finisher switch. 2. Check that the sensor and its mounting bracket are
correctly positioned. 3. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. Punch paper edge
sensor 1,2 and Punch PWB (YC5,YC7) 4. Replace the punch paper edge sensor 1,2.
Punch PWB 1. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. Punch PWB (YC1) and DF main
PWB (YC7) (3000-sheet finisher) Punch PWB (YC1) and DF main PWB (YC8)
(1000-sheet finisher) 2. Replace the Punch PWB.
DF main PWB Replace the DF main PWB
عطل كودي
رقم: Code: 8430
Description:Punch unit
communication error Communication with the punch unit is not possible
Causes:Punch
PWB. DF main PWB
Remedy:Punch
PWB 1. Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. Punch PWB (YC1) and DF main PWB (YC7)
(3000-sheet finisher) Punch PWB (YC1) and DF main PWB (YC8) (1000-sheet
finisher) 2. If the wiring is disconnected, shorted or grounded, replace the
wiring. 3. Replace the Punch PWB.
DF main PWB Replace the DF main PWB
عطل كودي
رقم: Code: 8500
Description:Mailbox
communication error (3000-sheet finisher) Communication failed to be
established after the mailbox was hooked up.
Causes:MB main
PWB. DF main PWB
Remedy:MB main
PWB 1. Turn the main power switch off and after 5 seconds, turn it on. 2.
Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. MB main PWB (YC3) and DF main PWB (YC6)
3. If the wiring is disconnected, shorted or grounded, replace the wiring. 4.
Replace the MB main PWB
DF main PWB Replace the DF main PWB
عطل كودي
رقم: Code: 8510
Description:MB
conveying motor error 1 (3000-sheet finisher) When initial operation, MB home
position sensor does not turn on within 5 s.
Causes:MB
conveying motor. MB home position sensor. MB main PWB
Remedy:MB
conveying motor 1. If the transfer roller won’t rotate smoothly, repair its
mechanism. 2. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. MB conveying motor and MB main
PWB (YC5) 3. If the wiring is disconnected, shorted or grounded, replace the
wiring. 4. Replace the MB conveying motor.
MB home position sensor 1. Execute U241 Mail Box – Motor HP to check the
finisher switch. 2. Check that the sensor and its mounting bracket are
correctly positioned. 3. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. MB home position
sensor and MB main PWB (YC2) 4. Replace the MB home position sensor.
MB main PWB Replace the MB main PWB
عطل كودي
رقم: Code: 8520
Description:MB
conveying motor error 2 (3000-sheet finisher) When standby operation, MB home
position sensor does not turn off within 1 s.
Causes:MB
conveying motor. MB home position sensor. MB main PWB
Remedy:MB
conveying motor 1. Execute Mail Box – Conv of U240 finisher operation check. 2.
Manipulate the conveying roller of the mailbox to check it can smoothly rotate.
3. Check that the drive from the motor reaches the conveying roller. 4. Confirm
that the wiring connector is firmly connected and, if necessary, connect the
connector all the way in. MB conveying motor and MB main PWB (YC5) 5. If the
wiring is disconnected, shorted or grounded, replace the wiring. 6. Replace the
MB conveying motor.
MB home position sensor 1. Execute U241 Mail Box – Motor HP to check the finisher
switch. 2. Check that the sensor and its mounting bracket are correctly
positioned. 3. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. MB home position sensor and MB
main PWB (YC2) 4. Replace the MB home position sensor.
MB main PWB Replace the MB main PWB
عطل كودي
رقم: Code: 8800
Description:Document
finisher main program error Document finisher main program error at power up
Causes:DF main
PWB. Engine PWB
Remedy:DF main
PWB 1. Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. DF main PWB (YC4) and Engine PWB (YC18)
(3000-sheet finisher) DF main PWB (YC7) and Engine PWB (YC18) (1000-sheet
finisher) 2. If the wiring is disconnected, shorted or grounded, replace the
wiring. 3. Replace the DF main PWB.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 8900
Description:Document
finisher backup error Read and write data does not match 3 times in succession
Causes:DF main
PWB
Remedy:1.
Confirm that the wiring connector is firmly connected and, if necessary,
connect the connector all the way in. DF main PWB (YC4) and Engine PWB (YC18)
(3000-sheet finisher) DF main PWB (YC7) and Engine PWB (YC18) (1000-sheet
finisher) 2. If the wiring is disconnected, shorted or grounded, replace the
wiring. 3. Replace the DF main PWB.
عطل كودي
رقم: Code: 8990
Description:DF Setup
error When a bridge unit is undetectable in the state where DF is connected.
When a bridge unit is detected in the state where DF is not connected.
Causes:Bridge
unit Document finisher. DF main PWB. Engine PWB
Remedy:Bridge
unit Document finisher 1. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. DF main PWB (YC4) and
Engine PWB (YC18) (3000-sheet finisher) DF main PWB (YC7) and Engine PWB (YC18)
(1000-sheet finisher) 2. If the wiring is disconnected, shorted or grounded,
replace the wiring.
DF main PWB Replace the DF main PWB.
Engine PWB Replace the engine PWB.
عطل كودي
رقم: Code: 9000
Description:Document
processor communication error Communication with the document processor is not
possible.
Causes:DP main
PWB. Engine PWB
Remedy:DP main
PWB 1. Check that the versions of the main unit firmware and the DP firmware
are identical. 2. Confirm that the wiring connector is firmly connected and, if
necessary, connect the connector all the way in. DP main PWB(YC1) and Engine
PWB(YC33) Engine PWB (YC3) and Main PWB (YC64) 3. If the wiring is
disconnected, shorted or grounded, replace the wiring. 4. Replace the DP main
PWB
Engine PWB Replace the engine PWB.
عطل كودي
رقم: Code: 9010
Description:Coin
vender communication error A communication error from coin vender is detected
10 times in succession
Causes:U206
setting. Coin vender control PWB. Engine PWB
Remedy:U206
setting Set maintenance mode U206 to off when a coin vender is not installed.
Coin vender control PWB 1. Confirm that the wiring connector is firmly
connected and, if necessary, connect the connector all the way in. Coin vender
control PWB and Engine PWB (YC22) 2. If the wiring is disconnected, shorted or
grounded, replace the wiring. 3. Replace the Coin vender control PWB.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
عطل كودي
رقم: Code: 9040
Description:DP lift
motor going up error When the DP lift motor is driven, DP lift sensor 1 does
not turn on within 1500 pulse. (Three recovery times.) The above has been
detected 5 times. * : The number of detection should be weighted with one for
the rise at job start and two for the irregular rise during transpoting. The
accumulated number must be cleared at completion of a normal rise. The default
threshold is 5.
Causes:DP lift
motor. DP lift sensor 1. DP main PWB
Remedy:DP lift
motor 1. Execute U906 Separating Operation Release. 2. Execute U243 Lift Motor
to check the DP motor operation. 3. Check that the original document lift guide
can move upwards. 4. Confirm that the wiring connector is firmly connected and,
if necessary, connect the connector all the way in. DP lift motor and DP main
PWB (YC5) 5. If the wiring is disconnected, shorted or grounded, replace the
wiring. 6. Replace the DP lift motor.
DP lift sensor 1 1. Execute U244 Lift L-Limit to check DP switch. 2. Check that
the sensor and its mounting bracket are correctly positioned. 3. Confirm that
the wiring connector is firmly connected and, if necessary, connect the
connector all the way in. DP lift sensor 1 and DP main PWB (YC4) 4. Replace the
DP lift sensor 1.
DP main PWB Replace the DP main PWB
عطل كودي
رقم: Code: 9050
Description:DP lift
motor going down error When the DP lift motor is driven, DP lift sensor 2 does
not turn on within 1500 pulse. (Three recovery times.) The above has been
detected 5 times.
Causes:DP lift
motor. DP lift sensor 2. DP main PWB
Remedy:DP lift
motor 1. Execute U906 Separating Operation Release. 2. Execute U243 Lift Motor
to check the DP motor operation. 3. Check that the original document lift guide
can move downwards. 4. Confirm that the wiring connector is firmly connected
and, if necessary, connect the connector all the way in. DP lift motor and DP
main PWB (YC5) If the wiring is disconnected, shorted or grounded, replace the
wiring. 5. Replace the DP lift motor.
DP lift sensor 2 1. Execute U244 Lift L-Limit to check DP switch. 2. Confirm
that the DP lift sensor 2 has been firmly fitted. 3. Confirm that the wiring
connector is firmly connected and, if necessary, connect the connector all the
way in. DP lift sensor 2 and DP main PWB (YC2) 4. Replace the DP lift sensor2.
DP main PWB Replace the DP main PWB
عطل كودي
رقم: Code: 9060
Description:DP
EEPROM error Mismatch of reading data from two locations occurs 3 times
successively. Mismatch between writing data and reading data occurs 3 times
successively.
Causes:DP main
PWB. Device damage of EEPROM
Remedy:DP main
PWB 1. Execute U906 Separating Operation Release. 2. Confirm that the EEPROM
has been properly installed. 3. Replace the DP main PWB
Device damage of EEPROM Contact the Service Support.
عطل كودي
رقم: Code: 9070
Description:Communication
error between DP and SHD A communication error is detected
Causes:DP SHD
PWB
Remedy:DP SHD
PWB 1. Execute U906 Separating Operation Release. 2. Confirm that the wiring
connector is firmly connected and, if necessary, connect the connector all the
way in. DP SHD PWB (YC1) and DP main PWB (YC10) 3. If the wiring is
disconnected, shorted or grounded, replace the wiring. 4. Replace the DP SHD
PWB.
عطل كودي
رقم: Code: 9080
Description:LED
fault detection A block is existent below a peak which was obtained by
activating the LEDs in the four CIS blocks at power on, which is less than
80hex.
Causes:DP CIS.
DP SHD PWB
Remedy:DP CIS
1. Execute CIS automatic original document alignment by U411. 2. Confirm that
the wiring connector is firmly connected and, if necessary, connect the
connector all the way in. CIS and DP SHD PWB (YC2) DP SHD PWB (YC1) and DP main
PWB (YC10) 3. If the wiring is disconnected, shorted or grounded, replace the
wiring. 4. Replace the CIS and execute U411.
DP SHD PWB Replace the DP SHD PWB.
عطل كودي
رقم: Code: 9100
Description:Coin
vender control PWB error Communication error has been detected at the coin mec
of the coin vender control PWB.
Causes:Coin
vender control PWB
Remedy:Replace
the coin mec.
عطل كودي
رقم: Code: 9110
Description:Coin
vender rejector error Communication error has been detected in connection with
the coin mec and the rejector.
Causes:Rejector
Remedy:1. Check
that the rejector is firmly installed and, if not, install firmly. 2. Replace
the rejector.
عطل كودي
رقم: Code: 9120
Description:Sensor
error in coin vender change (Yen 10) Change is empty despite change is enough
Causes:Coin jam
in the change tube. Contact in the connector. Change empty sensor. Coin vender
control PWB
Remedy:Coin jam
in the change tube Check visually and remedy.
Contact in the connector Check the connection of the empty change sensor.
Change empty sensor Replace the coin mec.
Coin vender control PWB Replace the coin mec.
عطل كودي
رقم: Code: 9130
Description:Sensor
error in coin vender change (Yen 50) Change is empty despite change is enough
Causes:Coin jam
in the change tube. Contact in the connector. Change empty sensor. Coin vender
control PWB
Remedy:Coin jam
in the change tube Check visually and remedy.
Contact in the connector Check the connection of the empty change sensor.
Change empty sensor Replace the coin mec.
Coin vender control PWB Replace the coin mec.
عطل كودي
رقم: Code: 9140
Description:Sensor
error in coin vender change (Yen 100) Change is empty despite change is enough
Causes:Coin jam
in the change tube. Contact in the connector. Change empty sensor. Coin vender
control PWB
Remedy:Coin jam
in the change tube Check visually and remedy.
Contact in the connector Check the connection of the empty change sensor.
Change empty sensor Replace the coin mec.
Coin vender control PWB Replace the coin mec.
عطل كودي
رقم: Code: 9150
Description:Sensor
error in coin vender change (Yen 500) Change is empty despite change is enough.
Causes:Change
tube. Contact in the connector. Change empty sensor. Coin vender control PWB
Remedy:Change
tube Check no exchange jam is observed at the outlet and, if necessary, repair
it.
Contact in the connector Check the connection of the empty change sensor.
Change empty sensor Replace the coin mec.
Coin vender control PWB Replace the coin mec.
عطل كودي
رقم: Code: 9160
Description:Coin
vender pay-out error Coin is paid out despite the pay-out motor is determined
not active.
Causes:Pay-out
motor
Remedy:Pay-out
motor Replace the coin mec.
عطل كودي
رقم: Code: 9170
Description:Coin
vender pay-out sensor error Coin is paid out despite the pay-out motor is
determined not active.
Causes:Pay-out
area. Pay-out motor. Pay-out sensor
Remedy:Pay-out
area Check no exchange jam is observed at the outlet and, if necessary, repair
it.
Pay-out motor Replace the coin mec.
Pay-out sensor Replace the coin mec.
عطل كودي
رقم: Code: 9180
Description:DP
feed-shift motor error The HP cannot be detected even after executing the HP
detection retrial 3 consecutive times. HP detection: when the DP feed-shift
motor is driven to move to the HP, the HP is not detected after it is rotated
once.
Causes:DP feed-shift
motor. DP feed-shift sensor
Remedy:DP
feed-shift motor 1. Unplug the power cord from the wall outlet, and wait five
seconds. Then plug in the power cord and then turn on the power switch. 2.
Confirm that the connector of the DP feed-shift motor is firmly connected, and
if necessary, push the unit all the way in. 3. Confirm that the wiring
connector is firmly connected, and if necessary, connect the connector all the
way in. 4. If the wire is disconnected, short-circuited or has a ground fault,
or the connector pin is deformed, replace the wire. 5. Replace the DF
feed-shift motor.
DP feed-shift sensor 1. Rotate the DP feed-shift motor manually to check that
it is not unusually difficult to rotate. 2. Check if the DP feed-shift sensor
is out of position because it has dropped off and if the sensor light is
interrupted by the actuator. 3. Confirm that the wiring connector is firmly
connected, and if necessary, connect the connector all the way in. 4. If the
wiring is disconnected, short-circuited or has a ground fault, replace the
wire. 5. Replace the DP feed-shift sensor.
عطل كودي
رقم: Code: 9500
Description:Image
processing circuit fault (Platen side)
Causes:Main
PWB. Engine PWB
Remedy:1.
Reinsert the connector if its connection is loose. Main PWB (YC65 and Engine
PWB (YC37) 2. Replace the main PWB. 3. Replace the Engine PWB 4. Contact the
Service Support.
عطل كودي
رقم: Code: 9510
Description:Image
processing circuit fault (DP side)
Causes:Main
PWB. DP SHD PWB
Remedy:1.
Reinsert the connector if its connection is loose. DP relay PWB (YC2) and DP
SHD PWB (YC3) 2. Replace the main PWB. 3. Replace the DP SHD PWB. 4. Contact
the Service Support.
عطل كودي
رقم: Code: F000
Description:Communication
error between main PWB and operation PWB
Causes:Main
PWB. Operation PWB
Remedy:Main PWB
1. Turn the main power swtch off and after 5 seconds, then turn power on. 2.
Check that the wirings and connetors between the main circuit PWB and the
operation circuit PWB and between the main circuit PWB and the HDD are normal.
Main PWB (YC12,YC6) and Operation PWB (YC5,YC8) 3. Check that the DDR memories
in the main circuit PWB are well conducted and, if not, replace. 4. Execute
U024 to initialize (FULL) the HDD. 5. Execute U021 to initialize memory. 6.
Replace the Main PWB. 7. Copy the log File saved in the HDD by U964 in USB
memory and contact the service support.
Operation PWB Replace the operation PWB.
عطل كودي
رقم: Code: F010
Description:Main PWB
checksum error
Causes:Defective
main PWB.
Remedy:1. Turn
the main power swtch off and after 5 seconds, then turn power on. 2. If not
corrected, replace the main PWB.
عطل كودي
رقم: Code: F020
Description:System
memory error Controller detection error
Causes:Defective
main PWB
Remedy:1. Turn
the main power swtch off and after 5 seconds, then turn power on. 2. If not
corrected, replace the main PWB.
عطل كودي
رقم: Code: F021
Description:System
memory error Controller detection error
Causes:Defective
main PWB
Remedy:1. Turn
the main power swtch off and after 5 seconds, then turn power on. 2. If not
corrected, replace the main PWB.
عطل كودي
رقم: Code: F022
Description:System
memory error Controller detection error
Causes:Defective
main PWB
Remedy:1. Turn
the main power swtch off and after 5 seconds, then turn power on. 2. If not
corrected, replace the main PWB.
عطل كودي
رقم: Code: F040
Description:Communication
error between Main PWB and Print engine
Causes:Main
PWB. Engine PWB. HDD
Remedy:Main PWB
1. Turn the main power swtch off and after 5 seconds, then turn power on. 2.
Repair or replace the wire from the engine PWB, that may be grounded. (Check
short-circuit between 5V and 3.3V.) 3. Check that the FCC wire connecting
between the main PWB (YC3) and the engine PWB (YC46) is normal and, if
necessary, re-insert.Or, replace the FCC wire. 4. If not corrected, replace the
main PWB.
Engine PWB 1. Check the engine software and upgrade to the latest, if
necessary. 2. Replace the engine PWB.
HDD Replace the HDD.
عطل كودي
رقم: Code: F041
Description:Communication
error between Main PWB and Scanner engine
Causes:Main
PWB. Engine PWB
Remedy:Main PWB
1. Turn the main power swtch off and after 5 seconds, then turn power on. 2.
Check that the wires between the main PWB and the engine PWB are normal. 3. If
not corrected, replace the main PWB.
Engine PWB Replace the Engine PWB.
عطل كودي
رقم: Code: F050
Description:Print
engine ROM checksum error
Causes:Engine software.
Engine PWB
Remedy:Engine software
Install the latest engine software.
Engine PWB 1. Turn the main power
swtch off and after 5 seconds, then turn power on. 2. Confirm that the EEPROM
has been properly installed. 3. If not corrected, Replace the engine PWB.
عطل كودي
رقم: Code: F051
Description: Scanner
engine ROM checksum error
Causes: Scanner
software. Engine PWB
Remedy: Scanner
software Install the latest scanner software.
Engine PWB 1. Turn the main power
swtch off and after 5 seconds, then turn power on. 2. Confirm that the EEPROM
has been properly installed. 3. If not corrected, Replace the Engine PWB.
عطل كودي
رقم: Code: F052
Description: Panel ROM checksum error
Causes: Panel software. Main PWB
Remedy: Panel software Install the latest panel software.
Main PWB 1. Turn the
main power swtch off and after 5 seconds, then turn power on. 2. Repair or
replace the wire from the engine PWB, that may be grounded. (Check
short-circuit between 5V and 3.3V.) 3. Check that the FCC wire connecting
between the main PWB (YC64, YC65) and the engine PWB (YC3, YC37) is normal and,
if necessary, re-insert.Or, replace the FCC wire. If not corrected, replace the
main PWB.
شكرا لزيارتكم موقع ماكينات تصوير ديجيتال ريكو و كيوسيرا